{"product_id":"breezaire-wine-cellar-cooling-unit-wksl-2200","title":"Breezaire Wine Cellar Cooling Unit WKSL 2200","description":"\u003ch2\u003eBreezaire WKSL 2200 Split Wine Cellar Cooling System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBreezaire WKSL 2200\u003c\/strong\u003e is a ductless split wine cellar cooling system designed for properly constructed and insulated wine cellars up to approximately \u003cstrong\u003e265 cubic feet\u003c\/strong\u003e. The system separates the evaporator and condenser into two modules, allowing the condenser to be installed away from the wine cellar for greater installation flexibility and reduced sound inside the cellar.\u003c\/p\u003e\n\u003cp\u003eThe WKSL 2200 uses Breezaire's \u003cstrong\u003eSentry III+ Digital Control System\u003c\/strong\u003e to provide selectable temperature control between \u003cstrong\u003e48°F and 63°F\u003c\/strong\u003e. The system also provides humidity management, with relative humidity generally maintained between \u003cstrong\u003e50% and 75%\u003c\/strong\u003e, depending on cellar and ambient conditions.\u003c\/p\u003e\n\u003cp\u003eThe split configuration allows the condenser to be positioned up to \u003cstrong\u003e50 feet from the wine cellar\u003c\/strong\u003e. Separating the condenser from the evaporator can help reduce operating noise within the cellar, while vibration-dampening features help minimize vibration in the wine storage environment.\u003c\/p\u003e\n\u003cp\u003eThe WKSL 2200 requires \u003cstrong\u003eprofessional HVAC or refrigeration installation\u003c\/strong\u003e. Installation includes copper refrigerant-line connections, low-voltage control wiring, electrical connections, refrigerant charging, and system testing. Proper cellar construction, including adequate insulation, a vapor barrier, sealed doors, and appropriate condenser ventilation, is important for proper system performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCooling System Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; border: 1px solid #d9d9d9; margin: 20px 0; font-size: 15px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eSystem Type\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eDuctless Split System\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eRecommended Cellar Capacity\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eUp to 265 cu. ft.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eTemperature Range\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003e48–63°F\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eControl System\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eSentry III+\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eHumidity Control\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eHumidity Range\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003e50–75% RH\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eHigh Temperature Alarm\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eDigital Display\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003ePower-Outage Protection\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eRefrigerant\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eR-134a\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003e110V \/ 60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eInstallation\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eProfessional HVAC or Refrigeration Required\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eFan Coil Weight\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003e25 lbs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eCondenser Weight\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003e35 lbs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eRemote Condenser\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eUp to 50 ft.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eOptional Bottle Probe\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Components\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; border: 1px solid #d9d9d9; margin: 20px 0; font-size: 15px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eComponent\u003c\/div\u003e\n\u003cdiv style=\"width: 30%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eDimensions\u003c\/div\u003e\n\u003cdiv style=\"width: 30%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eWeight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eFan Coil \/ Evaporator\u003c\/div\u003e\n\u003cdiv style=\"width: 30%; box-sizing: border-box; padding: 12px;\"\u003e14.125\" H × 14.125\" W × 7.75\" D\u003c\/div\u003e\n\u003cdiv style=\"width: 30%; box-sizing: border-box; padding: 12px;\"\u003e25 lbs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eCondenser\u003c\/div\u003e\n\u003cdiv style=\"width: 30%; box-sizing: border-box; padding: 12px;\"\u003e14.125\" H × 14.125\" W × 11\" D\u003c\/div\u003e\n\u003cdiv style=\"width: 30%; box-sizing: border-box; padding: 12px;\"\u003e35 lbs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 265 Cu. Ft. Cellar Capacity:\u003c\/strong\u003e Designed for properly constructed and insulated wine cellars up to approximately 265 cubic feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctless Split-System Design:\u003c\/strong\u003e Separates the evaporator and condenser into two modules, providing installation flexibility for smaller wine cellar applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Condenser Placement:\u003c\/strong\u003e The condenser can be positioned up to 50 feet from the wine cellar, helping reduce sound inside the cellar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48–63°F Temperature Control:\u003c\/strong\u003e Provides selectable temperature settings designed for controlled wine storage conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSentry III+ Digital Controls:\u003c\/strong\u003e Provides digital temperature control and monitoring along with alarm and power-outage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Humidity Support:\u003c\/strong\u003e Helps maintain relative humidity levels generally between 50% and 75%, depending on cellar and ambient conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration-Dampening Design:\u003c\/strong\u003e Vibration-minimizing components help reduce vibration within the wine cellar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Metal Cabinet:\u003c\/strong\u003e The WKSL 2200 includes a metal cabinet designed for long-term use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation:\u003c\/strong\u003e The system requires installation by a qualified HVAC, air-conditioning, or refrigeration technician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Bottle Probe:\u003c\/strong\u003e A Bottle Probe can measure the temperature of liquid inside a wine bottle rather than relying only on surrounding air temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; border: 1px solid #d9d9d9; margin: 20px 0; font-size: 15px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eRequirement\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px; background: #f5f5f5; font-weight: 600;\"\u003eDetails\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eProfessional Installation\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eQualified HVAC, air-conditioning, or refrigeration technician required.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eRefrigerant Lines\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eCopper refrigerant-line connections required between system components.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eControl Wiring\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eLow-voltage control wiring required.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eElectrical Connections\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eElectrical connections required as part of installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eRefrigerant Charging\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eRequired during installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eCondenser Ventilation\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eContinuous fresh air supply and adequate ventilation required.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eCondenser Ambient Temperature\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eBelow 85°F.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"width: 40%; box-sizing: border-box; padding: 12px;\"\u003eService Access\u003c\/div\u003e\n\u003cdiv style=\"width: 60%; box-sizing: border-box; padding: 12px;\"\u003eAdequate service access required for the condenser.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eWine Cellar Construction Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe WKSL 2200 is designed for properly constructed wine cellars. The size and construction of the cellar can significantly affect cooling requirements and system performance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation:\u003c\/strong\u003e Proper insulation should be used throughout the wine cellar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVapor Barrier:\u003c\/strong\u003e A properly constructed vapor barrier is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed Doors:\u003c\/strong\u003e Cellar doors should be properly sealed to minimize air leakage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass Exposure:\u003c\/strong\u003e Glass doors and walls can increase the cooling load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSun Exposure:\u003c\/strong\u003e Direct sunlight can increase the heat load placed on the cooling system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Leakage:\u003c\/strong\u003e Excessive air infiltration can increase cooling requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCellar Shape and Height:\u003c\/strong\u003e Ceiling height and cellar configuration can affect system sizing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCellar Sizing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTo estimate the volume of a wine cellar, multiply the length by the width by the height. For example, an 8 ft. × 6 ft. × 5.5 ft. cellar has a volume of approximately \u003cstrong\u003e264 cubic feet\u003c\/strong\u003e, which is within the WKSL 2200's stated capacity of up to 265 cubic feet under normal conditions.\u003c\/p\u003e\n\u003cp\u003eActual cooling requirements depend on more than cellar volume. Insulation quality, vapor-barrier construction, glass exposure, ambient temperature, sun exposure, door openings, air leakage, ceiling height, and cellar configuration can all affect the required cooling capacity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRecommended Accessory\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBreezaire Bottle Probe:\u003c\/strong\u003e The optional Bottle Probe measures the temperature of liquid inside a wine bottle rather than only the surrounding cellar air. This provides an additional method of monitoring actual wine temperature within the cellar.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Breezaire","offers":[{"title":"Default Title","offer_id":66999272669555,"sku":"WKSL-2200","price":3613.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/4020\/0307\/files\/WKSL2200Breezaire.png?v=1763967211","url":"https:\/\/primewinecoolers.com\/products\/breezaire-wine-cellar-cooling-unit-wksl-2200","provider":"Prime Wine Coolers","version":"1.0","type":"link"}